{"id":8296,"date":"2017-01-20T01:23:15","date_gmt":"2017-01-20T01:23:15","guid":{"rendered":"http:\/\/localhost\/sdi\/www\/cz-cz\/research-abstracts\/research-abstracts-riva-silver-research\/"},"modified":"2017-06-08T02:35:59","modified_gmt":"2017-06-08T02:35:59","slug":"research-abstracts-riva-silver-research","status":"publish","type":"page","link":"https:\/\/www.sdi.com.au\/cz-cz\/downloads\/research-abstracts\/research-abstracts-riva-silver-research\/","title":{"rendered":"Research abstracts &#8211;  Riva Silver research"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_row_inner el_class=&#8221;no-padding&#8221; el_id=&#8221;top&#8221;][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<h1 class=\"withimage_noindent\">Riva Silver research<\/h1>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;15px&#8221; el_class=&#8221;emty_basic&#8221;][vc_column_text]<strong>Riva silver\u00a0<\/strong><\/p>\n<p><strong>Performance<\/strong><\/p>\n<p>Al-Naimi O.; McCabe J. F.; Comparing the Compressive Strength of Riva Silver GIC with that of Other Competitor Products; University of New Castle, 2005.<\/p>\n<p>Purpose: T o measure the compressive strengths of a number of alloy reinforced glass ionomer cements. The method used would follow ISO9917-1:2003.<\/p>\n<p>Materials and Methods: Following the \u201cISO9917-1:2003\u201d standard, split moulds and plates were used to make 40 disc specimens, divided into groups of 10, (with 6 + 0.1 mm height and 4 + 0.1 mm diameter) from each one of the following restorative glass-ionomer cements (A total of 120 specimens) and following the manufactuerers\u2019 instructions:<\/p>\n<ul>\n<li>Riva Silver (SDI Ltd.)<\/li>\n<li>Miracle Mix (GC)<\/li>\n<li>Ketac Silver (3M\/Espe)<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_empty_space height=&#8221;100px&#8221; el_class=&#8221;emty_basic&#8221;][vc_single_image image=&#8221;954&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][\/vc_row_inner][vc_column_text]Results: The mean compressive strengths and standard deviatio (SD) of all materials after 1 hr, 1 week and 1 month, are shown in table 1 . The compressive strength of each material increased gradually with time reaching a maximum at 1 month for Ketac Silver (178.2 + 16.5) and Miracle Mix (211.7 + 15.8 Mpa), and at 1 week for Riva Silver (204.5 + 10.3).<\/p>\n<p>&nbsp;<\/p>\n<table style=\"padding: 15px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"10\">\n<tbody>\n<tr>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\"><strong>Testing<\/strong><\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\"><strong>Ketac Silver<\/strong><\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\"><strong>Miracle Mix<\/strong><\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\"><strong>Riva Silver<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">1 hr<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">97.8 (7.9)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">122.6 (4.7)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">134.3 (2.9)<\/td>\n<\/tr>\n<tr>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">1 day<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">155.4 (4.5)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">175.3 (8.7)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">179.0 (4.6)<\/td>\n<\/tr>\n<tr>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">1 week<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">163.8 (6.6)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">207.6 (11.9)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">204.5 (10.3)<\/td>\n<\/tr>\n<tr>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">1 month<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">178.2 (16.5)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">211.7 (15.8)<\/td>\n<td style=\"height: 50px; vertical-align: middle; padding: 10px;\">203.0 (14.6)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Table: 1<\/p>\n<p>Riva Silver had significantly the highest compressive strength at 1 hr, while Ketac Silver had significantly the lowest values at all times.[\/vc_column_text][vc_column_text]<a href=\"mailto:info@sdi.com.au?subject=Request%20for%20Full%20Copy%20of%20Research%20-%20Ref%20No.%20107\">Request Full Copy<\/a>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_row_inner el_class=&#8221;no-padding&#8221; el_id=&#8221;top&#8221;][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text] Riva Silver research [\/vc_column_text][vc_empty_space height=&#8221;15px&#8221; el_class=&#8221;emty_basic&#8221;][vc_column_text]Riva silver\u00a0 Performance Al-Naimi O.; McCabe J. F.; Comparing the Compressive Strength of Riva Silver GIC with that of Other Competitor &hellip; <a href=\"https:\/\/www.sdi.com.au\/cz-cz\/downloads\/research-abstracts\/research-abstracts-riva-silver-research\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Research abstracts &#8211;  Riva Silver research&#8221;<\/span><\/a><\/p>\n","protected":false},"author":14,"featured_media":0,"parent":8188,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/internal-page.php","meta":{"_acf_changed":false,"_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"footnotes":"","_tec_slr_enabled":"","_tec_slr_layout":"","_wp_rev_ctl_limit":""},"class_list":["post-8296","page","type-page","status-publish","hentry"],"acf":[],"ticketed":false,"_links":{"self":[{"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/pages\/8296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/comments?post=8296"}],"version-history":[{"count":2,"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/pages\/8296\/revisions"}],"predecessor-version":[{"id":11101,"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/pages\/8296\/revisions\/11101"}],"up":[{"embeddable":true,"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/pages\/8188"}],"wp:attachment":[{"href":"https:\/\/www.sdi.com.au\/cz-cz\/wp-json\/wp\/v2\/media?parent=8296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}